monitor_early_media_ring
Created by Ryan Harris, last modified by livem Chan on 2020.07.29
monitor_early_media_ring
string Monitors early media for a user-specific ring tone. Each time the tone is heard, the switch will increment an internal counter for that leg. Once the counter reaches monitor_early_media_ring_total
(or this variable has not been set) then the early media will be sent.
The syntax is a series of !
delimited early media conditions in the following format:
condition_name:number_of_hits:tone_detect_frequencies
condition_name | user defined name for the error condition |
---|---|
number_of_hits | the number of times the tone must be heard before considering it a fail |
tone_detect_frequencies | the frequencies to listen for (delimited by + instead of ,). See tone_detect |
this variable only works when ignore_early_media
is set to true.
Usage
<action application="bridge" data="{monitor_early_media_ring_total=3,monitor_early_media_ring=usring:1:440.0+480.0!ukring:2:400+450}sofia/gateway/yourgateway/1239@conference.freeswitch.org"/>